Top
News Center

Bus processing machine: bus connection mode

  • Author:Kunkai special CNC Equipment Co., LTD
  • Origin:http://www.kksk.cn/
  • Time of issue:2012-09-05 00:00

Bus processing machine: bus connection mode

  • Origin:http://www.kksk.cn/
  • Time of issue:2012-09-05 00:00

Bus processing machine is one of our main products. Small make up for you to share bus bar manufacturing machine fault: the oil temperature of busbar processing oil temperature gauge indicates the transformer top oil temperature, oil temperature in operation of the monitoring point is 85 ℃, temperature rise is refers to the transformer top oil temperature minus the ambient temperature, in the operation of the transformer in the outside temperature 40 ℃, the temperature rise shall not exceed 55 ℃, running will be subject to the top oil temperature, temperature rise is a reference data. If the transformer under the same conditions (environmental temperature, load, oil level, etc.), the oil temperature is 10℃ higher than usual or the load is unchanged but the temperature is rising, and the cooling device is in normal operation, it is considered that the transformer has internal failure (should pay attention to whether the thermometer error or failure). The temperature rise standard of transformer in China is based on the ambient temperature of 40℃, so the top oil temperature of transformer shall not exceed 40℃+55℃=95℃. If the top oil temperature exceeds 95℃, the temperature of the internal coil will exceed the heat resistance strength of the coil insulation. In order to make the insulation not aging too fast, the monitoring of the top oil temperature of the transformer should be controlled below 85℃. Internal cause of transformer temperature anomaly temperature anomaly caused by the failures of the transformer internal fault such as turn-to-turn short circuit or short circuit between the layers, coil for folding screen discharge, internal fever, joint lead core multipoint earthing increased eddy current overheat, unbalanced zero sequence current and magnetic flux leakage form with iron tank circuit and fever caused by factors such as the transformer temperature anomalies, or differential protection will also be accompanied by gas Action, serious fault may also make explosion-proof tube or pressure release valve oil injection, then the transformer should be stopped checking. Abnormal temperature is caused by abnormal operation or failure of the cooler, such as shutdown of the submersible oil pump, damage of the fan, scaling of the heat dissipation pipe, poor cooling efficiency, and failure of the radiator valve. The cooling system should be maintained and flushed in time or a backup cooler should be put in place, otherwise transformer load should be adjusted. If the temperature indicator has error or malfunction, the thermometer should be replaced.

More information: http://www.kksk.cn/

 

Keyword:

CONTACT INFORMATION

Yunnan multifunctional fillet machine - Yunnan bus bar processing machine - Kunming copper bar processing machine

 

Service hotline: 0871-68310369  13608805685  18587197072

 

e-mail address: crazer70@qq.com

 

Company address: No. 1028, Haiyuan Middle Road, national high tech Industrial Development Zone, Kunming

ONLINE MESSAGE

Username used for comment:
客户留言
Description:
验证码

Copyright: Kunming KUNKAI special numerical control equipment Co., Ltd. Yunnan ICP preparation No. 11004860-1 website construction: China Enterprise Power Kunming SEO